Blog

ESOS Phase 4 and ISO 50001: Does Your Certification Cover the Energy You Need to Report?

Check whether your ISO 50001 certification covers ESOS Phase 4 energy use, when a separate audit is needed and what you still need to submit through MESOS.
ESOS Phase 4 and ISO 50001: Does Your Certification Cover the Energy You Need to Report?

A manufacturer may hold an ISO 50001 certificate for its two main factories and still need an Energy Savings Opportunity Scheme (ESOS) audit. For Phase 4, the question is which parts of the business’s energy use the certified management system covers. If the company also operates a fleet or a separate distribution depot, those activities can change the answer.

You can use a qualifying ISO 50001 certificate as your sole assessment route if it covers your total energy consumption or all the significant energy consumption you identify for ESOS. If your certificate leaves any of the energy you need to assess uncovered, you can combine certification with an ESOS energy audit. Compare your group structure, energy records and certificate scope to work out which route applies.

‍

Start with the organisation that qualifies for ESOS

Start by identifying the ESOS participant. This is the organisation or group whose energy use the assessment covers. The Phase 4 qualification date is 31 December 2026. A UK undertaking meets the large-undertaking thresholds if it employs at least 250 people, or if its annual turnover exceeds £44 million and its annual balance sheet total exceeds £38 million. If one UK undertaking qualifies, other UK undertakings in the same group can come into scope. The employee test uses the monthly average over the relevant accounting period. If your business is close to a threshold, check its earlier accounts as well. An undertaking normally retains its size classification until it meets the criteria for the other size for two consecutive accounting periods.

Map your group structure on the qualification date and check any later acquisitions or disposals under the scheme’s group rules. Compare your site and company lists with your certification documents. If one company operates the factories and another runs distribution, check which undertaking receives and uses each energy supply. Review any premises added since certification, along with site moves and shared premises where billing arrangements make energy responsibility harder to establish.

Next, calculate the participant’s total energy consumption across its relevant UK buildings, industrial processes, transport and any other energy use. Use one reference period of 12 consecutive months that includes 31 December 2026 and ends before the compliance date of 5 December 2027. A calendar-year 2026 reference period can work if your records support it. Where invoices span different dates, reconcile them to the chosen period. Use verifiable data where reasonably practicable. If you estimate any part of total energy consumption, disclose the use of estimates in your notification and keep the reason, method and supporting data in your evidence pack.

Give each site or activity a row in a spreadsheet. Record the undertaking, supply type, consumption, source and certificate coverage. Ask finance to reconcile bills and fuel purchases. Have estates, operations and fleet teams check the list against the assets and activities they manage. If the factory has a dedicated gas meter for process equipment, check that its readings appear only once in the site total.

At a newly occupied depot, use the opening meter reading, billing dates and agreement for the supply to establish what the business received and used during the relevant period. A landlord’s recharge or a combined invoice may need supporting records to establish which energy use belongs in the assessment. If a supply is shared, ask who has the underlying readings and how usage has been allocated. Keep the allocation with the source records so it can be checked when the figures are reviewed.

‍

Check the scope of your ISO 50001 certificate

Read the scope and check the supporting schedule

ISO 50001 is a standard for managing and improving energy performance. For ESOS, its value depends on the activities and assets included in the certified energy management system. Start with the certificate’s scope statement and any supporting site schedule. Compare these with the records that show how the system manages energy, such as energy reviews, metering records and the activities assigned to each location.

A factory address may include production lines, a warehouse and a yard for company vehicles. Check which of those activities fall within the scope of the certificate. If finance holds fuel records centrally, match them to the vehicles and operations they relate to. Resolve ambiguous wording with the certification body before counting the associated energy as covered.

An estimate can fill a gap in the consumption data. To establish coverage, you need the certificate and the records that support its scope. Allow for any unconfirmed activities in the audit budget until you have checked them.

‍

Check the issue date, validity and accreditation

For Phase 4, the certificate must have been issued on or after 6 December 2023 and be valid on 5 December 2027. It must also come from a certification body that meets the scheme’s accreditation requirements. The Environment Agency accepts certification bodies accredited by the United Kingdom Accreditation Service (UKAS), by an EU member state’s national accreditation body or by a member of the International Accreditation Forum. Check the Environment Agency’s Phase 4 compliance routes and certificate requirements.

If renewal falls before the compliance date, put it on the same timetable as the ESOS assessment. Review what the renewed certificate is expected to cover and check the issued documents before relying on them. If your plan depends on adding a recently acquired site or an activity such as fleet operations, leave time to verify the updated scope and arrange an audit if one is needed.

‍

Work out whether certification covers enough of your energy use

Once you have calculated your total energy consumption, you can select assets and activities that account for at least 95% of that total as your significant energy consumption. You can leave up to 5% outside the audit or certification coverage as de minimis energy. Record those exclusions in your evidence pack and report both total and significant energy consumption in your notification. If you choose to assess total energy consumption, your assessment routes must cover the full amount.

Apply the coverage test to energy use on a consistent basis. Counting certified locations gives a misleading picture if some buildings are much larger, run longer hours or host energy-intensive production. Convert electricity, gas and transport fuel to kilowatt-hours (kWh) for a like-for-like comparison. That also gives you the figures you need to calculate energy intensity ratios.

‍

A worked example for a manufacturing group

Suppose a UK group uses 10 million kWh in its chosen reference period. Its certified factory operations account for 9.2 million kWh. The group also uses 550,000 kWh in its fleet and 250,000 kWh at a distribution depot. Both are within the group’s ESOS energy total and outside the certificate. Assume the certificate meets the scheme’s other conditions.

The factories give the group 92% coverage through certification. Adding an audit of the depot alone would raise coverage to 94.5%. If the group instead audits the fleet, the combined routes would cover 9.75 million kWh, or 97.5% of the total. The group could identify the certified factories and the audited fleet as its significant energy consumption and document the remaining 2.5% at the depot as de minimis. Its total energy consumption would still be 10 million kWh.

If the qualifying certificate already covered both the factories and fleet, the group could use ISO 50001 alone to cover that same selected significant energy consumption. If the group chose to assess its full energy total, the depot would also need coverage. Use the same breakdown when comparing the cost and timing of an audit with expanding the certificate’s scope. Give the people quoting for the work a clear list of the assets and activities you need to cover.

Use the figures to agree the ESOS budget. Show the person approving it what the certificate covers, which activities need further assessment and which records could change the calculation. If you are close to 95%, check how a corrected meter reading or a revised fleet fuel total would affect the result before committing to the route. A material revision to total consumption can change the audit scope even when the certificate itself stays the same.

‍

Plan the work that follows the coverage decision

When ISO 50001 can serve as the sole assessment route

If qualifying certification covers your total energy consumption or all your selected significant energy consumption, you are exempt from the separate ESOS audit, lead assessor and ESOS report requirements. You still need to calculate energy consumption and intensity figures, keep an evidence pack and obtain sign-off from the appropriate director or equivalent officer. Submit your compliance notification through Manage your Energy Savings Opportunity Scheme Reporting (MESOS) by 5 December 2027. Include the certificate number and validity dates, the assets and activities it covers, and the percentage of total energy consumption they account for.

An intensity ratio shows how much energy the organisation uses in relation to a meaningful measure of activity. A manufacturer might use kWh per tonne of product for industrial processes. Calculate at least one ratio for each applicable category: buildings, transport, industrial processes and other energy use. Base the ratios on the energy scope you chose for the assessment. Keep the calculations and the reasons for choosing each measure so the director can trace the figures back to the underlying records.

‍

When you need both certification and an audit

If the certificate leaves a gap in the applicable energy use, commission ESOS audit work to cover it. For the combined route, prepare an ESOS report that shows how the certificate and audit together cover the required energy. You generally need an ESOS lead assessor from an approved register to review the assessment. Participants with total energy consumption under 40,000 kWh can use the lead assessor exception. Where this exemption is used, two directors or equivalent responsible officers must provide sign-off. Two are also required where the lead assessor is internal to the participant. Record the assets covered by each route and allow time for director sign-off before submitting the notification.

A targeted audit can help you investigate energy use that has received less attention. For example, a fleet review can flag journeys or operating practices to examine and help you identify the data you need to evaluate a fuel-saving measure. A distribution site may justify a closer look at lighting schedules or electricity use outside operating hours. Rank potential actions by expected energy reduction, cost and practicality so the people approving investment can compare them on a consistent basis.

‍

Keep the evidence and action plan on the same timetable

KKeep the certificate, scope documents, consumption figures and supporting records together. Retain your Phase 4 evidence pack until at least 5 December 2035. Record the energy covered by each assessment route and add any audit and sign-off documentation that applies. Keep a copy of the notification in the evidence pack. The Environment Agency’s Phase 4 guidance asks responsible undertakings to share relevant ISO 50001 evidence with their group undertakings, unless disclosure is prohibited by law.

Keep your Phase 3 action plan and progress records if they apply to you. Record which measures you implemented, when you put them into practice and how you estimated the energy savings. Where a previous action plan requires review, identify commitments you do not expect to deliver by 5 December 2027 and explain why. Include that explanation in the Phase 4 notification and in the ESOS report where required. The notification requirements for earlier commitments and achieved savings can also apply when you use ISO 50001 alone.

Energy-consuming Phase 4 participants, including those using ISO 50001 alone, must submit a Phase 4 action plan by 5 December 2028. The annual progress updates follow on 5 December 2029, 5 December 2030 and 5 December 2031.

Our work with Edge View Homes shows how ESOS audits, action planning and progress reporting fit together. During Phase 3, Focus Green managed the company’s energy audits and notification, then prepared its action plan and first progress update. Read the Edge View Homes case study.

‍

Ask Focus Green to review your ESOS Phase 4 scope

If you already hold ISO 50001 certification, start with a review of how its scope matches the energy use you need to assess. Focus Green can help you check your Phase 4 position, review energy data across buildings, operations and transport, and identify where ESOS audit work may be required. That review gives you a clearer basis for budgeting and scheduling the work.

For an initial conversation, have your certificate and scope schedule to hand, together with your site and company lists and the latest available utility and transport records. If you have a previous ESOS assessment or action plan, mention it when you enquire. These records help us identify where to begin and what further evidence would help.

If you need an audit, we can help define the scope, explain the lead assessor requirements and support you with reporting and submission. We can also identify practical energy-saving measures and estimate their costs and potential savings. Speak to Focus Green about your ESOS Phase 4 assessment.

Industry Accreditations & Affiliations

UK's No.1 Energy Compliance Survey Provider

energy accessor conducting commercial energy audit in the uk

Full UK Coverage

We cover all parts of the UK. We can cater to even the most complex and widespread commercial property portfolios.

energy accessor conducting commercial energy audit in the uk

Trained and Accredited

Our multi-skilled assessment team is certified by several accreditation bodies and undergoes regular training to develop their skillset.

energy accessor conducting commercial energy audit in the uk

Dedicated Project Managers

We provide each of our valued customers with their own Dedicated Project Manager, ensuring you always have a direct point of contact.

energy accessor conducting commercial energy audit in the uk

24-Hour Initial Response Time

We provide 24/7 customer support, guaranteeing swift responses to urgent inquiries and ensuring peace of mind.

energy accessor conducting commercial energy audit in the uk

Flexible Contract Options

Our solutions are designed to be flexible, adapting to market fluctuations to help you manage costs and mitigate risks effectively.

energy accessor conducting commercial energy audit in the uk

Seamless Supplier Transition

We facilitate seamless transitions and manage contracts efficiently, minimising disruptions and ensuring a consistent energy supply.

Contact Our Dedicated Team

Are you looking for top-notch Energy Audits, Assessments, Consultations or Energy Management Services? Contact our experienced professionals today!

With offices strategically located across the United Kingdom, we guarantee high-quality services for your project, regardless of location.